Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 497-507, 2021.
Article in English | WPRIM | ID: wpr-918860

ABSTRACT

All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient’s inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient’s requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

2.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 9-12, 2016.
Article in English | WPRIM | ID: wpr-202734

ABSTRACT

OBJECTIVES: In this study we evaluated heat generation during the low-speed drilling procedure without irrigation. MATERIALS AND METHODS: Ten artificial bone blocks that were similar to human D1 bone were used in this study. The baseline temperature was 37.0degrees C. We drilled into 5 artificial bone blocks 60 times at the speed of 50 rpm without irrigation. As a control group, we drilled into an additional 5 artificial bone blocks 60 times at the speed of 1,500 rpm with irrigation. The temperature changes during diameter 2 mm drilling were measured using thermocouples. RESULTS: The mean maximum temperatures during drilling were 40.9degrees C in the test group and 39.7degrees C in the control group. Even though a statistically significant difference existed between the two groups, the low-speed drilling did not produce overheating. CONCLUSION: These findings suggest that low-speed drilling without irrigation may not lead to overheating during drilling.


Subject(s)
Humans , Dental Implants , Hot Temperature
3.
The Journal of Korean Academy of Prosthodontics ; : 111-119, 2015.
Article in Korean | WPRIM | ID: wpr-87267

ABSTRACT

PURPOSE: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). MATERIALS AND METHODS: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. RESULTS: The mean deviation of the insertion point and angulation were 0.28 mm and 0.26degrees, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. CONCLUSION: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.


Subject(s)
Axis, Cervical Vertebra , Cone-Beam Computed Tomography , Mandible , Maxilla , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL